HOME >>
Devices
Microwave Device
.
Devices
Microwave Generator
Magnetron is used to generate microwave. The device can generate stable output of microwave.
|
6kW Microwave Generator (transformer type)
| P/N |
UM-6000HB |
| Power Supply for Anode |
High Voltage Circuits with AC Transformer |
| Magnetron |
H3882(our own spec) |
| Frequency |
2455MHz±15MHz |
| Microwave Output |
0.5~6kW |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Cooling Methods |
Power Supply Unit: Forced air Oscillation Unit: Water |
| Dimensions |
Power Supply Unit: 600(W) x 645(D) x 1300(H) mm Oscillation Unit: 290(W) x 411(D) x 334(H) mm |
| Weight |
Power Supply Unit: approx. 260kg Oscillation Unit: approx. 18kg |
| Commercial Power |
3φAC200V 50/60Hz 30A |
※Other Specs Available ・12kW Generator (6kW x two) ・18kW Generator (6kW x three) ・24kW Generator (6kW x four) | |

|
|
3kW Microwave Generator (transformer type)
| P/N |
UM-3000HB |
| Power Supply for Anode |
High Voltage Circuits with AC Transformer |
| Magnetron |
2M252(our own spec) |
| Frequency |
2455MHz±15MHz |
| Microwave Output |
0.3~3kW |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Cooling Methods |
Power Supply Unit: Forced air Oscillation Unit: Water |
| Dimensions |
Power Supply Unit: 700(W) x 570(D) x 1400(H) mm Oscillation Unit: 290(W) x 411(D) x 334(H) mm |
| Weight |
Power Supply Unit: approx. 220kg Oscillation Unit: approx. 18kg |
| Commercial Power |
3φAC200V 50/60Hz 16A |
※Other Specs Available ・6kW Generator(3kW x two) ・12kW Generator (3kW x four) | |

|
|
1.5kW Microwave Generator (transformer type)
| P/N |
UM-1500EC-B |
| Power Supply for Anode |
High Voltage Circuits with AC Transformer |
| Magnetron |
2M130(our own spec) |
| Frequency |
2455MHz±15MHz |
| Microwave Output |
0.1~1.5kW |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Cooling Methods |
Power Supply Unit: Forced air Oscillation Unit: Forced air |
| Dimensions |
Power Supply Unit: 336(W) x 400(D) x 201(H) mm Oscillation Unit: 315(W) x 267(D) x 232(H) mm |
| Weight |
Power Supply Unit: approx. 35kg Oscillation Unit: approx. 11 kg |
| Commercial Power |
1φAC200V 50/60Hz 20A | |

|
|
6kW Microwave Generator (Switching type)
| P/N |
UM-6000-IS |
| Power Supply for Anode |
High Voltage Circuits with Switch-Mode |
| Magnetron |
H3882(our own spec) |
| Frequency |
2455MHz±15MHz |
| Microwave Output |
0.5~6kW |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Cooling Methods |
Power Supply Unit: Water Oscillation Unit: Water |
| Dimensions |
Power Supply Unit: 480(W) x 570(D) x 200(H) mm Oscillation Unit: 290(W) x 411(D) x 334(H) mm |
| Weight |
Power Supply Unit: approx. 55kg Oscillation Unit: approx. 18 kg |
| Commercial Power |
3φAC200V 50/60Hz 30A | |

|
|
3kW Microwave Generator(Switching type)
| P/N |
UM-3000-IS-B |
| Power Supply for Anode |
High Voltage Circuits with Switch-Mode |
| Magnetron |
2M252(our own spec) |
| Frequency |
2455MHz±15MHz |
| Microwave Output |
0.3~3kW |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Cooling Methods |
Power Supply Unit: Water Oscillation Unit: Water |
| Dimensions |
Power Supply Unit: 480(W) x 570(D) x 200(H) mm Oscillation Unit: 290(W) x 411(D) x 334(H) mm |
| Weight |
Power Supply Unit: approx. 26kg Oscillation Unit: approx. 18kg |
| Commercial Power |
3φAC200V 50/60Hz 16A | |

|
|
1.5kW Microwave Generator(Switching type)
| P/N |
UM-1500-IS-B |
| Power Supply for Anode |
High Voltage Circuits with Switch-Mode |
| Magnetron |
H3181(our own spec) |
| Frequency |
2455MHz±15MHz |
| Microwave Output |
0.1~1.5kW |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Cooling Methods |
Power Supply Unit: Forced Air Oscillation Unit: Forced Air |
| Dimensions |
Power Supply Unit: 480(W) x 510(D) x 150(H) mm Oscillation Unit: 316(W) x 267(D) x 230(H) mm |
| Weight |
Power Supply Unit: approx. 15kg Oscillation Unit: approx. 11kg |
| Commercial Power |
3φAC200V 50/60Hz 8A | |

|
Magnetron
Electronic device to generate 2450MHz microwave
|
Magnetron 1.5kW
| P/N |
2M130(our own spec) |
| Output Power |
1500W (1.5kW) |
| Frequency |
2455MHz±15MHz |
| Cooling Methods |
Forced Air |
| Weight |
approx. 2.3kg | |

|
|
Magnetron 3kW
| P/N |
2M252(our own spec) |
| Output Power |
3000W (3kW) |
| Frequency |
2455MHz±15MHz |
| Cooling Methods |
Water |
| Weight |
approx. 3.5kg | |

|
|
Magnetron 6kW
| P/N |
H3882(our own spec) |
| Output Power |
6000W (6kW) |
| Frequency |
2455MHz±15MHz |
| Cooling Methods |
Water |
| Weight |
approx. 2.5kg | |

|
Waveguides
These devices can propagate microwave efficiently and are used for the connection of Generator and Applicator.
|
H-Corner Waveguide
| Propagation Mode |
TE10 |
| Max. Transmission Power |
6000W max |
| Adaptable Frequency |
2450MHz±50MHz |
| VSWR |
1.2 max. |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) | |

|
|
E-Corner Waveguide
| Propagation |
TE10 |
| Max. Transmission Power |
6000W max |
| Adaptable Frequency |
2450MHz±50MHz |
| VSWR |
1.2 max. |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) | |

|
|
Straight Waveguide
| Propagation |
TE10 |
| Max. Transmission Power |
Confirmed up to 10kW |
| Adaptable Frequency |
2450MHz±50MHz |
| VSWR |
1.1 max. |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Length |
3m max. | |

|
Isolator
The device can absorb microwave power reflected from the applicator to protect the magnetron in the generator.
|
Water Cooled Type Isolator
| P/N |
IM-5000 |
| Allowable Power |
6000W max. at average 7500W max. at peak |
| Adaptable Frequency |
2450MHz±25MHz |
| Input VSWR |
1.2 max. |
| Forward Insertion Loss |
0.3dB max. |
| Reverse Insertion Loss |
18dB min. |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Cooling Methods |
Water |
| Dimensions |
200(W)×450(D)×107(H) |
| Weight |
約6.4kg | |

|
|
Air Cooled Type Isolator
| P/N |
IM-1500S |
| Allowable Power |
1500W max. at average 4500W max. at peak |
| Adaptable Frequency |
2450MHz±25MHz |
| Input VSWR |
1.2 max. |
| Forward Insertion Loss |
0.3dB max. |
| Reverse Insertion Loss |
18dB min. |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Cooling Methods |
Forced Air |
| Dimensions |
200(W)×326(D)×327(H)mm |
| Weight |
approx. 7kg |
| Commercial Power |
1φAC200V 50/60Hz 16VA | |

|
Power Monitor
The device can monitor microwave power propagated in the monitoring waveguide. Reflected power can be reduced to adjust the EH tuner to minimize the displayed reflected power of the power monitor.
|
PM10-DM
| P/N |
PM10-DM |
| Display |
Digital |
| Adaptable Frequency |
2450MHz±30MHz |
| Monitoring Power Range |
0~6kW |
| Monitoring Direction |
Forward & Reverse (Incident wave & Reflected wave) |
| VSWR |
3.0 max |
| Accuracy |
±100W max. at 2kW max. ±5% max. at higher than 2kW |
| External Output |
Voltage, RS232C |
| Dimension/Weight |
210(W)×230(D)×73(H)mm / 2.2kg |
| Commercial Power |
1φAC85~264V 50/60Hz 30VA | |

|
|
PM10-AM
| P/N |
PM10-AM |
| Display |
Analog (Analog meter) |
| Adaptable Frequency |
2450MHz±30MHz |
| Monitoring Power Range |
0~6kW |
| Monitoring Direction |
Forward & Reverse (Incident wave & Reflected wave) |
| VSWR |
3.0 max. |
| Accuracy |
±100W max. at 2kW max. ±5% max. at higher than 2kW |
| External Output |
Voltage, RS232C |
| Dimension/Weight |
210(W)×230(D)×73(H)mm / 2.2kg |
| Commercial Power |
1φAC85~264V 50/60Hz 30VA | |

|
|
PM10-BI
| P/N |
PM10-BI |
| Display |
Non |
| Adaptable Frequency |
2450MHz±30MHz |
| Monitoring Power Range |
0~6kW |
| Monitoring Direction |
Forward & Reverse (Incident wave & Reflected wave) |
| VSWR |
3.0 max. |
| Accuracy |
±100W max. at 2kW max. ±5% max. at higher than 2kW |
| External Output |
Voltage |
| Dimension/Weight |
168(W)×140(D)×63(H)mm / 1.0kg |
| Commercial Power |
1φAC85~264V 50/60Hz 30VA | |

|
|
Wavegide Monitor
A monitor comes with each PM10-DM, PM10-AM, PM10-BI.
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Dimensions |
161(W)×150(D)×106.5(H)mm |
| Weight |
約1.1kg | |

|
|
PMS-BX
| P/N |
PMS-BX |
| Display |
Analog (Analog meter) |
| Adaptable Frequency |
2450MHz±30MHz |
| Monitoring Power Range |
0~6kW |
| Monitoring Direction |
One-way(Reflection Wave) |
| VSWR |
3.0 max. |
| Dimensions |
110(W)×110(D)×60(H) |
| Weight |
Approx. 0.3kg |
| Commercial Power |
Not necessary | |

|
|
Waveguide for PMS-BX
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Dimensions |
161(W)×150(D)×106.5(H) |
| Weight |
approx. 1.1kg | |

|
EH Tuner
The device can reduce microwave power of reflected wave from applicator.
|
Electric EH-Tuner TM-5000/E
| P/N |
TM-5000/E |
| Power Input |
6000kW max. |
| Adaptable Frequency |
2450MHz±25MHz |
| Matching Level |
1.2max. (Load VSWR) |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Dimensions |
200(W)×352(D)×297(H)mm |
| Weight |
approx. 6kg |
| Commercial Power |
1φAC100V 50/60Hz 0.14A | |

|
|
Manual EH-Tuner TM-5000/M
| P/N |
TM-5000/M |
| Power Input |
6000kW max. |
| Adaptable Frequency |
2450MHz±25MHz |
| Matching Level |
1.2max. (Load VSWR) |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Dimensions |
200(W)×340(D)×285(H)mm |
| Weight |
約4kg | |

|
Visual Sensor
|
Simple spatial microwave visual sensor,"HOTARU" i.e. Firefly
LED will light in response to intense microwaves near PC board.
You can visualize the intensity and distribution of microwaves in the microwave heating furnace.
| P/N |
MHL-1230 RG |
| Adaptable Frequency |
2450MHz±50MHz |
| Emission Color |
Red & Green |
| Dimensions |
300(W)×120(D)×2.7(H)mm |
| Materials of PC board |
Epoxy Glass |
| Number of sensors |
360 (12 x 30 pieces) | |


|
|
Electric field distribution visual sensor for waveguide, "Wave Viewer"
LED will light in response to microwaves in waveguide.
You can visualize the intensity of microwaves in waveguides, such as standing waves.
| P/N |
MWV-300 |
| Adaptable Waveguide |
WRI-22(WRJ-2) (IEC: R22 ; EIA: WR430) |
| Adaptable Flange |
FUDR22(BRJ-2) (IEC: UDR22 ; EIA: UG1716/U) |
| Length of waveguide |
300mm |
| Emission Color |
Red |
| Materials of PC board |
Epoxy Glass |
| Maximum power |
7kW at peak (At matched load) |
| Emission Sensitivity |
Starts emitting slightly at peak of 300W | |

|
Leak Detector
Leak Detector(LD10M)
The device to monitor leakage level of microwave from the 2.45GHz microwave equipment
| P/N |
LD10M |
| Adaptable Frequency |
2450MHz±30MHz |
| Power Range |
0.1~10mW/cm² |
| Power Indication |
Analog meter (exponential) |
| Dimensions |
Display: 74(W)x154(D)x52(H)mm Antenna unit: 300(W)x34(D)x34(H) mm |
| Weight |
approx. 0.9kg |
| Power |
DC6V (4 AA batteries) | |

|